Cissell DX4 CONTROLLER Manual de usuario

Busca en linea o descarga Manual de usuario para Lavadoras Cissell DX4 CONTROLLER. BULLETIN - Automated Laundry Systems Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PO Box 990 Ripon, WI 54971-0990 (920) 748-3121
Page 1 of 18 FB08-15
BULLETIN
Field
Bulletin No. FB08-15
Date July 2008
Product Type IPSO and Cissell Washer-Extractors and Tumblers
Purpose Announcement
Interchangeable N/A
Subject Error Codes
On the following pages is a list of error codes for the IPSO and Cissell line of Washer-Extractors
and Tumblers. For additional information on the programming of these machines refer to the
Programming Manual.
Control Types
Micro 9
Micro 20
PC 30
PS40
PS40F
Sigma
DX4
Cygnus
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - BULLETIN

PO Box 990 Ripon, WI 54971-0990 (920) 748-3121Page 1 of 18 FB08-15BULLETINFieldBulletin No. FB08-15Date July 2008Product Type IPSO and Cis

Pagina 2 - Page 2 of 18 FB08-15

Error CodesPage 10 of 18 FB08-15A9 Motor thermal protector was activated.• Check the following: a. motorb. motor connectionsc. contactorsd. input volt

Pagina 3 - Page 3 of 18

Error CodesFB08-15 Page 11 of 18Table 5FH There is a hardware problem (fault on printed circuit board) •Replace print boardError Code Probable Cause P

Pagina 4 - Page 4 of 18 FB08-15

Error CodesPage 12 of 18 FB08-15Control Type: SIGMATable 6Error Code Probable Cause Possible Corrective ActionsE3 (E Prom) E Prom has a faulty value.

Pagina 5 - Page 5 of 18

Error CodesFB08-15 Page 13 of 18Additional information for SIGMA• BOOT 100 appears on the display during Start up or Boot Memory - E Prom. • Additiona

Pagina 6 - Page 6 of 18 FB08-15

Error CodesPage 14 of 18 FB08-15Control Type: DX4NOTE: If there is a gas failure the electronic ignition of the gas heated tumbler will only try to fu

Pagina 7 - Page 7 of 18

Error CodesFB08-15 Page 15 of 18Control Type: CygnusNOTE: Errors 1-32 display only when a Cygnus control machine is NOT running.Error Code Probable Ca

Pagina 8 - Page 8 of 18 FB08-15

Error CodesPage 16 of 18 FB08-15ERROR 13 (Temperature Error) At startup, the temperature is higher than 95o C or after 6 minutes the temperature is st

Pagina 9 - Page 9 of 18

Error CodesFB08-15 Page 17 of 18Table 8NOTE: Errors 50-59 display only when a Cygnus control machine IS running.ERROR 26 (New ID Chip Error) Error whe

Pagina 10 - Page 10 of 18 FB08-15

Error CodesPage 18 of 18 FB08-15Table 9ERROR 52 (Drain Error) Water level is not lowered within 2cm after 2 minutes upon completion of a wash cycle (M

Pagina 11 - Replace print board

Error CodesPage 2 of 18 FB08-15Control Type: Micro 9NOTE: In the event of an error the control will generate an error message at the end of the cycle.

Pagina 12 - Page 12 of 18 FB08-15

Error CodesFB08-15 Page 3 of 18NOTE: * To clear the not 3 error code: coin or vended machines - go to program D and press ECO button (E). OPL models -

Pagina 13 - Page 13 of 18

Error CodesPage 4 of 18 FB08-15Control Type: Micro 20NOTE: When a malfunction occurs during a program, the central display will communicate the approp

Pagina 14 - Page 14 of 18 FB08-15

Error CodesFB08-15 Page 5 of 18Table 3EA (tilt switch) Tilt switch was activated 15 times, skipping the final spin.•Check load size and type• Inspect

Pagina 15 - Page 15 of 18

Error CodesPage 6 of 18 FB08-15Control Type: PC30Error Code Probable Cause Possible Corrective Actions00 Programming key in wrong place.•Correct posit

Pagina 16 - Page 16 of 18 FB08-15

Error CodesFB08-15 Page 7 of 18Table 411 Level switch detects water in the drum at the start of a cycle.•Inspect inlet water valves• Inspect drain val

Pagina 17 - Page 17 of 18

Error CodesPage 8 of 18 FB08-15Additional information for the PC30 and KEB Frequency Controller• There is a test program built into the PC30 - the acc

Pagina 18 - Page 18 of 18 FB08-15

Error CodesFB08-15 Page 9 of 18Control Type: PS40 and PS40FNOTE: Alarm codes are used to alert the operator to problems with the machine function. The