Cissell DX4 CONTROLLER Manual de usuario Pagina 17

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 16
Error Codes
FB08-15 Page 17 of 18
Table 8
NOTE: Errors 50-59 display only when a Cygnus control machine IS running.
ERROR 26 (New ID Chip Error) Error when inserting new ID
Chip
Verify correct chip is received
for machine type
ERROR 27 (Invalid File Size
Error)
Incorrect file size
Check correct file size is
programmed
ERROR 28 (RTC Read Error) Error when reading RTC
Verify correct RTC is in
machine
Check wiring
ERROR 29 (RTC Writer Error) Error by a writing action to the
RTC
Program correct action to the
RTC
Check wiring
ERROR 30 (EProm Read Error) Error when reading EProm
Verify correct EProm is in
machine
Check wiring
ERROR 31 (EProm Write Error) Error by a writing action to the
EProm
Program correct action to the
EProm
Check wiring
ERROR 32 (Water Level Too
Low)
The water level was too low
during the heating cycle
Check inlet water supply
Inspect inlet water valves
Inspect drain valve
Check water level switch
Error Code Probable Cause Possible Corrective Actions
ERROR 50 (Level Stop Error) The programmed water level is
not reached in a certain time
Check inlet water supply
Inspect inlet water valves
Inspect drain valve
Check water level switch
ERROR 51 (Heat Stop Error) The programmed temperature is
not reached in a certain time
Check auxillary heating system
Inspect temperature sensor
Check water safety level
switch
Error Code Probable Cause Possible Corrective Actions
Vista de pagina 16
1 2 ... 12 13 14 15 16 17 18

Comentarios a estos manuales