Error Codes
Page 6 of 18 FB08-15
Control Type: PC30
Error Code Probable Cause Possible Corrective Actions
00 Programming key in wrong
place.
•
Correct position of program
key
01 Not used
• No action required
02 Program selected does not exist.
• Select another program
03 Appears when processor is
energized the first time.
• No action required
03 Failure of RAM memory.
• Replace RAM memory
04 Water level not reached after 15
minutes.
• Check inlet water supply
• Inspect inlet water valves
• Inspect drain valve
• Check water level switch
06 Programmed temperature was
not reached after 60 minutes.
• Check auxillary heating system
• Inspect drain valve
• Check water level switch
07 Level switch detects water in the
drum at the end of the cycle.
• Inspect drain valve
• Check drain outlet
08 The temperature sensor or
temperature sensor circuit is
defective.
• Replace temperature sensor
• Repair sensor wiring
09 Motor thermal protector was
activated.
• Check the following:
a. motor
b. motor connections
c. contactors
d. input voltage
e. inverter
f. motor and machine
bearings
g. print board (old models
only)
10 Out of balance switch was
activated at the start of a cycle.
• Check load size and type
• Check for an unbalanced load
Comentarios a estos manuales