Error Codes
FB08-15 Page 15 of 18
Control Type: Cygnus
NOTE: Errors 1-32 display only when a Cygnus control machine is NOT running.
Error Code Probable Cause Possible Corrective Actions
ERROR 1 (Program Title Error) After installation of new display
board, the titles were not copied
from mainboard to the display
board
Copy titles to new display
board
ERROR 2 (Component
Unknown)
A wash component is unknown
in the wash program
Program new component
ERROR 3 (Component Error) Incorrect wash data - a wash
component is created with
incorrect length
Program correct wash data and
correct length
ERROR 4 (Subroutine not
found)
Refers to unknown component
Program new component
ERROR 5 (Wrong Password) Incorrect password is used for
entering test menu or editing
menu
Enter correct password
ERROR 6 (Wash Data Error) Incorrect or incomplete wash
data
Program correct or complete
wash data
ERROR 7 (Inverter
Communication Error)
No communication or
incomplete communication
between inverter and mainboard
Inspect wiring between
inverter and mainboard
ERROR 8 (Inverter Autotuning
Error)
Incorrect status during
autotuning
Check status during autotuning
ERROR 9 (Inverter Parameter
Error)
Writing of parameter is refused
or error during writing of
parameters to the inverter
Inspect wiring at inverter
Check parameter and
reprogram
ERROR 10 (Inverter Status
Error)
Error message on the inverter
Check inverter
ERROR 11 (Real Time Clock
Error)
Read-out error on the clock
Inspect wiring at clock
Check clock and reprogram
ERROR 12 (Tilt Switch Error) Incorrect functioning or
connection of the tilt switch
when you start a cycle
Check tilt switch
Inspect wiring to the tilt switch