Error Codes
FB08-15 Page 15 of 18
Control Type: Cygnus
NOTE: Errors 1-32 display only when a Cygnus control machine is NOT running.
Error Code Probable Cause Possible Corrective Actions
ERROR 1 (Program Title Error) After installation of new display
board, the titles were not copied
from mainboard to the display
board
•
Copy titles to new display
board
ERROR 2 (Component
Unknown)
A wash component is unknown
in the wash program
•
Program new component
ERROR 3 (Component Error) Incorrect wash data - a wash
component is created with
incorrect length
• Program correct wash data and
correct length
ERROR 4 (Subroutine not
found)
Refers to unknown component
• Program new component
ERROR 5 (Wrong Password) Incorrect password is used for
entering test menu or editing
menu
• Enter correct password
ERROR 6 (Wash Data Error) Incorrect or incomplete wash
data
• Program correct or complete
wash data
ERROR 7 (Inverter
Communication Error)
No communication or
incomplete communication
between inverter and mainboard
• Inspect wiring between
inverter and mainboard
ERROR 8 (Inverter Autotuning
Error)
Incorrect status during
autotuning
• Check status during autotuning
ERROR 9 (Inverter Parameter
Error)
Writing of parameter is refused
or error during writing of
parameters to the inverter
• Inspect wiring at inverter
• Check parameter and
reprogram
ERROR 10 (Inverter Status
Error)
Error message on the inverter
•
Check inverter
ERROR 11 (Real Time Clock
Error)
Read-out error on the clock
• Inspect wiring at clock
• Check clock and reprogram
ERROR 12 (Tilt Switch Error) Incorrect functioning or
connection of the tilt switch
when you start a cycle
• Check tilt switch
• Inspect wiring to the tilt switch
Comentarios a estos manuales