Error Codes
Page 8 of 18 FB08-15
Additional information for the PC30 and KEB Frequency Controller
• There is a test program built into the PC30 - the access code is E 227.
• The input voltages are 24 volts DC.
• The output voltages are 220 volts AC.
• The output of the PC30 motor relay to the inverter is 0 volts.
• The output of the PC30 soap relay is 0 volts.
• The drain time goes automatically witrh the spin time.
• The drain can be programmed (in seconds) with a spin.
• Programs 30 and 39 are fixed and cannot be deleted or modified.
• The door lock is controlled with its own print board.
• The door lock and unlock solenoid operate on 24 volts DC
• The door lock mechanism has 3 switches S1 (Door Closed switch input), S2 (Door Locked switch input) and
S3 (Stops the signal from the door lock print board to the door lock coil, when the S2 switch is closed and the
program starts).
• The resistor on the PC30 print board for the relay drain 1 has to be removed when the drain valve operates with
an addtional relay.